EasyManuals Logo

Lenze 9300 vector Series Mounting Instructions

Lenze 9300 vector Series
Go to English
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
Technical data
Safety relay K
SR
3
136
EDKVF9333V DE/EN/FR 7.2
Mounting conditions
Mounting place In the control cabinet
Mounting position Vertical
Free spaces
Dimensions
Weights
143
3.2 Safety relay K
SR
Terminal Description Field Values
X11/K32
X11/K31
X11/33
X11/34
Safety relay K
SR
1st disconnecting path
Coil voltage at +20 °C DC 24 V (20 ... 30 V)
Coil resistance at +20 °C 823 W ±10 %
Rated coil power Approx. 700 mW
Max. switching voltage AC 250 V, DC 250 V (0.45 A)
Max. AC switching capacity 1500 VA
Max. switching current (ohmic load) AC 6 A (250 V), DC 6 A (50 V)
Recommended minimum load > 50 mW
Max. switching rate 6 switchings per minute
Mechanical service life 10
7
switching cycles
Electrical service life
at 250 V AC
(ohmic load)
10
5
switching cycles at 6 A
10
6
switching cycles at 1 A
10
7
switching cycles at 0.25 A
at 24 V DC
(ohmic load)
6 × 10
3
switching cycles at 6 A
10
6
switching cycles at 3 A
1.5 × 10
6
switching cycles at 1 A
10
7
switching cycles at 0.1 A

Table of Contents

Other manuals for Lenze 9300 vector Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 9300 vector Series and is the answer not in the manual?

Lenze 9300 vector Series Specifications

General IconGeneral
BrandLenze
Model9300 vector Series
CategoryDC Drives
LanguageEnglish

Related product manuals