Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
3
137
EDKVF9333V DE/EN/FR 7.2
3.3 Operation with rated power (normal operation)
Note!
The controllers EVF9324, EVF9326 and EVF9328 EVF9333 may only be
operated with the prescribed mains chokes and mains filters.
3.3.1 Rated data for 400 V mains voltage
Basis of the data
Voltage Frequency
AC mains connection [V
rate
d
]
3/PE AC 320 V − 0 % ... 440 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
DC−mains connection
(alternatively)
[U
DC
] DC 450 V − 0 % ... 620 V + 0 % ˘
Output voltage
With mains choke 3 ~ 0 approx. 94 % V
rated
˘
Without mains choke 3 ~ 0 ... U
N
˘
9300 Mains current
1)
Typical motor power Output power Power loss
With
Mains choke
Without
Mains choke
ASM
(4−pole)
2/4 kHz
2)
8 kHz
2)
U, V, W U, V, W +U
G
, −U
G
3)
Type I
r
[A] I
r
[A] P
rated
[kW] P
rated
[hp] S
rated
[kVA] S
rated
[kVA] P
DC
[kW] P
loss
[W]
EVF9321−xV 1.5 2.1 0.37 0.5 1.0 1.0 1.9 50
EVF9322−xV 2.5 3.5 0.75 1.0 1.7 1.7 0.7 65
EVF9323−xV 3.9 5.5 1.5 2.0 2.7 2.7 0 100
EVF9324−xV 7.0 ˘ 3.0 4.0 4.8 4.8 2.0 150
EVF9325−xV 12.0 16.8 5.5 7.5 9.0 9.0 0 210
EVF9326−xV 20.5 ˘ 11.0 15.0 16.3 16.3 0 390
EVF9327−xV 29.0 43.5 15.0 20.0 22.2 22.2 10.2 430
EVF9328−xV 42.0 ˘ 22.0 30.0 32.6 32.6 4.0 640
EVF9329−xV 55.0 ˘ 30.0 40.0 41.6 41.6 0 810
EVF9330−xV 80.0 ˘ 45.0 60.0 61.7 61.7 5.1 1100
EVF9331−xV 100 ˘ 55.0 75.0 76.2 76.2 0 1470
EVF9332−xV 135 ˘ 75.0 100 103.9 103.9 28.1 1960
EVF9333−xV 165 ˘ 90.0 125 131.2 124.7 40.6 2400
1)
Mains currents at a switching frequency of 8 kHz
2)
Switching frequency of the inverter
3)
Power supplied by the DC bus when operating with power−adapted motor
˘ Operation allowed only with mains choke or mains filter