SET-UP AND INSTALLATION 16000 OPERATOR MANUAL
4-8
Published 05-09-17, Control # 011-29_v2
CRANE ASSEMBLY
Install Exhaust Pipes (Past Production)
IMPORTANT Perform following steps before starting
engine if equipped with Past Production (non-Tier 4)
removable exhaust outlet pipes as shown in Figure 4-6
.
See Figure 4-6
for the following procedure.
1. Remove rear enclosure panels (1, View A).
2. Unhook springs (4, View B) from clips (5) and remove
both rain caps (3) from shipping position.
3. Store rain caps (3) in enclosure frame (View A).
4. Remove both exhaust pipes (2) from shipping position
(View A).
5. Install both exhaust pipes (2) in working position (View
B).
6. Connect springs (4, View B) to clips (5).
7. Install rear enclosure panels (1).