16000 OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
3
LUFFING JIB SETUP MODE
For cranes with software version FCN 2.654 and newer, the
Luffing Jib Setup Mode must be turned on before the limits
identified in the center two columns of Table 3-3
can be
bypassed.
NOTE: The software version of your crane is shown in the
Manitowoc screen of the main display (see
Figure 3-35
).
1. Enter the function mode screen in the main display
(Figure 3-11
).
2. Scroll to and enter the setup screen (Figure 3-12
).
3. The screen shown in Figure 3-13
will appear.
4. Turn the luffing jib setup mode on (or off when done with
luffing jib setup).
5. Rotate limit bypass switch (D3) clockwise and release.
The limits will remain bypassed for 10 seconds.
6. Move the desired control handle (luffing hoist, boom
hoist, load drum) in the required direction. The limits will
remain bypassed for as long as the handle is moved in
either direction.
7. The limits will remain bypassed for 10 seconds after the
control handle(s) is returned to off.
NOTE: When the luffing jib setup mode is on, the crane
setup fault is turned on and the alarm in the cab
sounds intermittently.
Function
Mode
Screen
FIGURE 3-11
FIGURE 3-12
Access the Setup
Mode Screen
FIGURE 3-13
Luffing Jib
Setup Mode
I = ON
O = OFF

Table of Contents

Other manuals for Manitowoc 16000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 16000 and is the answer not in the manual?

Manitowoc 16000 Specifications

General IconGeneral
BrandManitowoc
Model16000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals