SET-UP AND INSTALLATION 16000 OPERATOR MANUAL
4-36
Published 05-09-17, Control # 011-29_v2
Node-6 Electrical Connections For MAX-ER With Mast Stop Limit Switch
NODE-6 CONFIGURATION WITH MAST
STOP LIMIT SWITCH
See Figure 4-22 for the following procedure.
NOTE: The following Node-6 configurations only apply to
MAX-ER
Ā®
attachments with mast stop limit switch
and crane software version M002066 or newer.
Check the crane display to verify mast stop cylinder
position sensor information screen is no longer
available.
Shipping Configuration (View A)
1. Connect terminating plug (2b, View A) to Node-6
receptacle (2a).
FIGURE 4-22
View A
1
2a3a4a
5a
2b
6a (behind)
5b
6b (behind)
View B
2c
2b
2d
2e
3b
3a 2a
View C
4b
2e
4c
2c
2b
2a3a4a
2d
3b
Legend
Item Component Description
1 Node 6 Front of Rotating Bed
2a Receptacle W66
Drum 1 in Boom Butt2b W66 Shorting Plug w/ Dust Cap
2c Cable W66
2d Cable W66P8
Mast Stop Positioning Sensor
2e W66P8 Shorting Plug w/ Dust Cap
3a Receptacle W63
Drum 3 in Boom Butt
3b Cable W63
4a Receptacle W64
Drum 5 in Mast Butt
4b Cable W64
4c Cable W64P8 Mast Stop Positioning Sensor
5a WN In CAN In
5b Cable WN24 or WN26 From Wireless Setup Receiver
6a WN Out CAN Out
6b Cable WN18 From Node 3