OPERATION 4 - 6
D-MAXE with OI-B/OI-Nwww.maxcessintl.com MI 2-296 1 D
Bedienung.fm
[0030] ASC is triggered.
These icons appear if the ASC function has been
activated and triggered on the selected drive and the
motor has been blocked.
[0200] The limit values of the encoder have been reached.
[0400] The optional oscillator ’OSC’ is available in the selected
job.
[0800] The optional controller ’PIC’ is available in the selected
job.
[4000] RCAL is active on the selected drive.
This symbol appears between the time when the first and
second key on the RCAL-20/26 is pressed.
[0008] SGC: Guiding depends on the web speed.
If this symbol is flashing, the web speed is equal to 0 and
no guiding is being performed.
[1000] The selected "device" is expecting MAXNET data from a
device, but does not receive any data. The device that
should send MAXNET data is either not connected or not
turned on.
[2000] The selected "device" expects data from a Gateway, but
does not receive any data, since no data can be received
on the Gateway.