4-15
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Open the control panel (See page 4-13).
Remove the knob from the selector. Use a
flat blade screwdriver, if needed.
Remove the two 5/16” hex head screws
from the front of the control panel.
Remove the selector switch from behind the
control panel.
The wire connectors for the selector switch
are marked by the terminals, B for Brown
and P for Purple. There are two of each
color.
1.
2.
3.
4.
5.
REMOVE SELECTOR
SWITCH - MN/CS
Two 5/16” Hex
Head Screws
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Open the control panel (See page 4-13).
Loosen the hex nut on the front of the
control panel with a pair of pliers. Unscrew
the nut from the switch. The hex nut part is
positioned closest to the control panel when
reinstalling it.
Remove the push-to-start switch from the
back of the control panel.
Remove two wire connectors from the
switch.
1.
2.
3.
4.
REMOVE PUSH TO START
SWITCH - MN/CS
Hex Nut
Push-to-start
Switch