"3072ES / 3772ES / 3772ES HD" Service & Parts Manual October 2008
Page 4-15
EZ-Cal
ADJUSTMENT
Table
continued
5F
OUTRIGGERS
5G
GROUND MODE
Lower Control Operations
5H
TILT
5I
OVERLOAD
CE: values apply
ANSI: values = 0
Sub Menu
5J
ALARMS
5K
Heights
5F-1
5F-2
5F-3
5F-4
5F-5
5F-6
5F-7
5F-8
5F-9
5F-10
5F-11
5G-1
5G-2
5G-3
5G-4
5G-5
5G-6
5H-1
5H-2
5H-3
5H-4
5I-1
5I-2
5I-3
5I-4
5I-5
5I-6
5I-7
5I-8
5I-8a
5I-8b
5J-1
5J-2
5J-3
5K-1
5K-2
5K-3
5K-4
5K-5
5K-6
5K-7
5K-8
OPERATION I D PERSONALITY
FACTORY SETTING EXPLAINATION
Outriggers 1=N 2=Y
Outrigger Test
Extend
Level
Retract
Debounce
Initial
Tilt Filter
X Tilt Target
Y Tilt Target
Tilt Slack
UP
DOWN
OUT
IN
Accel
Decel
X Trip
Y Trip
Delay Trip
Delay Clear
Trip @
Lamp @
Alarm @
@ Height
Safe Down
Delay Trip
Delay Clear
Overload #2
@ Height
Scale
Drive Yes/No
Lift
Tilt
Elevation @
Maximum Drive
Maximum Lift
Armguard
Overload
Safe Down
Overload #2
Tilt #2
2
Y / N
45 %
35 %
55 %
0.35 sec
0.5 sec
8
2 Degrees
2 Degrees
3 Degrees
75%
0 %
0 %
0 %
1.0 sec
1.0 sec
3.0 degrees
3.0 degrees
2.0 sec
0.5 sec
ANSI: 0% || CE: 110%
ANSI: 0% || CE: 0%
ANSI: 0% || CE: 0%
ANSI: 0% || CE: 8%
ANSI: 0% || CE: 12%
1.5 sec
1.5 sec
—
0%
100%
No
2 = Down
1 = When Elevated
0%
101%
ANSI: 101% || CE: 98%
101%
ANSI: 0% || CE: 8%
ANSI: 0% || CE: 12%
0%
ANSI: 0% || CE: 74%
Prevents drive when outrigger legs are down
Test feature (see outrigger section)
Maximum speed potential
Extend speed after pads touch down
Maximum speed potential
Compensates for switch bounce
Push outrigger legs when deployed / operated
Compensates for tilt sensor free movement
Target level stops movement
Target level stops movement
Variance to tilt target
Maximum speed potential
Gravity Down
Power deck operation (not used)
Power deck operation (not used)
Ramp up time to maximum
Ramp down to stop
Angle tilt sensor signals out of level
Angle tilt sensor signals out of level
Time delay between tip and signal
Time delay between clear tip and signal off
% of weight over maximum to trigger overload
% of weight over maximum to trigger lamp
% of weight over maximum to trigger alarm
% of elevation load sense starts monitoring weight
% of elevation lift down still operates in overload
Delay before overload trip
Delay before overload clear
Sub category, press ENTER to access
% of height for secondary overload valve
% of reduced overload valve
1 = FWD 2 = REV 3 = Both 4 = All Motion
1 = Up 2 = Down 3 = Both 4 = All Motion
1 = When Elevated 2 = Always
Maximum driveable height
Maximum elevated height potential
Stops descent for 5 sec
% of elevation load sense starts monitoring weight
% of elevation lift down still operates in overload
Not Used
Reduced degree of tilt at % elevation