Loading...
October 2008 "3072ES / 3772ES / 3772ES HD" Service & Parts Manual
Page 4-14
EZ-CAL ADJUSTMENT
EZ-Cal Adjustment is only possible in Access Level 1.
Access Level 1 is restricted.
Refer to
Access Level 1
on page 4-9.
EZ-Cal
ADJUSTMENT
Table
continued…
5A
DRIVE
(PLATFORM STOWED)
Sub Menu
5B
DRIVE -
ELEVATED
5C
LIFT
Sub Menu
5D
STEER
5E DECK
5A-1
5A-2
5A-3
5A-4
5A-5
5A-6
5A-7
5A-8
5A-8a
5A-8b
5B-1
5B-2
5B-3
5B-4
5B-5
5B-6
5C-1
5C-2
5C-3
5C-4
5C-5
5C-6
5C-7
5C-8
5C-8a
5C-8b
5D-1
5D-2
5D-3
5D-4
5D-5
5E–
OPERATION I D PERSONALITY
FACTORY SETTING EXPLAINATION
FWD Min
FWD Max
REV Min
REV Max
ACCEL
DECEL
MAX Height
Positrack
AUTO below
AUTO
FWD Min
FWD Max
REV Min
REV Max
ACCEL
DECEL
UP Min
UP Max
DOWN Min
DOWN Max
ACCEL
DECEL
Max Height
Armguard
Time
@ Height
Speed
Drive Compensation
Drive Comp Elevated
Accel
Decel
Not Used
5 %
100 %
5 %
100 %
1.5 sec
1.0 sec
101 %
Not Used
0%
2.0 sec
5 %
23 %
5 %
23 %
1.5 sec
1.0 sec
5 %
60 %
0 % (not used)
0 % (not used)
1.2 sec
0.5 sec
ANSI: 101 % || CE: 98%
0.0 sec
101 %
30 %
30 %
20 %
0.2 sec
0.2 sec
Not Used
Slowest speed possible
Maximum speed potential
Slowest speed possible
Maximum speed potential
Ramp up time to maximum
Ramp down to stop
Maximum Drivable Height
Not Used
Not Used
Not Used
Slowest speed possible
Maximum speed potential
Slowest speed possible
Maximum speed potential
Ramp up time to maximum
Ramp down to stop
Slowest speed possible
Maximum speed potential
Gravity down (not used)
Gravity down (not used)
Ramp up time to maximum
Ramp down to stop
Maximum height potential
CE Option Only
CE Option Only
CE Option Only
Maximum speed potential
Adds additional to drive speed
Adds additional to drive speed elevated
Ramp up time to maximum
Ramp down to stop
Power-out deck (not used)