October 2008 "3072ES / 3772ES / 3772ES HD" Service & Parts Manual
Page 4-16
EZ-CAL SETUP
EZ-Cal Setup is only possible in Access Level 1 or Access Level 2.
Access Level 1 and Access Level 2 are restricted.
Refer to
Access Level 1
on page 4-9.
EZ-Cal
SETUP
Table
6A
CHANGE DEFAULTS
6B
TILT SETUPS
6C
HEIGHT SETUP
(CE OPTION ONLY)
6D
LOAD SETUPS
(CE OPTION ONLY)
6E
INTERLOCKS
6A-1
6A-2
6B-1
6B-2
6B-3
6C-1
6C-2
6C-3
6C-4
6C-5
6C-6
6D-1
6D-2
6D-3
6E-1
6E-2
6E-3
Tilt Shutdown
Elevated Tilt Shutdown
Elevation @
Calibrate Height
Minimum Lift
Samples
Tilt Correction
Slow Down
Calibrate Load
Faulty Load
Dynamic Scale
Trigger Only
Trigger Wait
Function Hold
2 = Lift
1 = Lift & Drive
0 %
CE procedure
1.0 sec
0.10 sec
Disabled
10 %
CE procedure
100 %
95 %
10.0 sec
0.0 sec
0.2 sec
Function shut down tilted when platform stowed
Function shut down tilted when platform elevated
CE Option only
for calibration of CE Load Sense system
CE Option Only
CE Option Only
CE Option Only
CE Option Only
for calibration of CE Load Sense system
CE Option Only
CE Option Only
Delay enable pulled before timeout
Delay before function after enable pulled
Time function holds after enable released
OPERATION I D FUNCTION
FACTORY SETTING EXPLAINATION
Customer
Model Select
Charlie
3 = ANSI, No Outriggers
4 = ANSI, With Outriggers
5 = CE, No Outriggers
6 = CE, With Outriggers
Identifies MEC Aerial brand
Identifies model of machine
Calibrate Level? Y=ENTER – N=ESCPressing ENTER twice will calibrate level sensor
Ensure machine is on flat level surface before calibrating level sensor