"3072ES / 3772ES / 3772ES HD" Service & Parts Manual October 2008
Page 4-25
FUNCTION ACTIVE Messages
The following HELP messages indicate that there is no problem with the GP400 but that a function is
active – the vehicle should be moving as requested by the operator.
DRIVING! (no flash code)
LIFTING! (no flash code)
LOWERING! (no flash code)
STEERING! (no flash code)
EXTENDING OUTRIGGERS! (no flash code)
RETRACTING OUTRIGGERS! (no flash code)
CALIBRATION Messages
The following are “calibration” HELP messages – until the machine is properly calibrated for height
and/or pressure (as required), many functions will not be available.
NOT CALIBRATED --------------------------------------------------------------------------- Flash Code: 1/1
FUNCTIONS LOCKED - NOT CALIBRATED ------------------------------------------ Flash Code: 1/1
• The height and/or pressure sensors have not been calibrated and are required because of the setup of the
GP400.
• If overload functions are active (ADJUSTMENTS/OVERLOAD TRIP@, LAMP@ or ALARM@ set to a non-zero
value) then both the height and pressure sensors must be calibrated.
• If overload functions are not active, but height-based decisions are active (ADJUSTMENTS/HEIGHT values set
to between 1% and 100%) then the height sensors must be calibrated.
• Calibration procedures are accessible from the SETUPS/HEIGHT SETUPS and SETUPS/LOAD SETUPS
menus.
FAULT: CUSTOMER ------------------------------------------------------------------------- Flash Code: 1/1
• The system must be configured to the customer requirements – with the EZ-Cal in SETUPS/CHANGE
DEFAULTS menu, select Charlie.
SHUTDOWN Help Messages
This section lists “shutdown” HELP messages – functions can be shut down to prevent them being
used:
SHUTDOWN - CHECK EMS SWITCHES! ---------------------------------------------- Flash Code: 2/1
• The Base/Platform selector switch position indicates the mode in which the system must operate if both are
active together; the system does not know how to function
FUNCTIONS LOCKED - TEST MODE SELECTED----------------------------------- Flash Code: 2/2
•Test mode is not accessible with this system. Switch power off/on to reset to normal operation
FUNCTIONS LOCKED - ARMGUARD (CE option only)---------------------------- Flash Code: 2/2
•During descent, the System can stop movement for a configurable time, to allow a safety check that no-one is
close to the machine. The operator must release and re-select DOWN to continue lowering (after the delay
timeout).
• If the armguard feature is not wanted, set ADJUSTMENTS/LIFT/ ARMGUARD/TIME to 0.0s.