EasyManua.ls Logo

Meggitt VM600 - Connecting Vibration and Pressure Sensors

Meggitt VM600
362 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VM600 MPS hardware manual (standard version) MAMPS-HW/E 9 - 5
Edition 17 - February 2018
Connecting vibration and pressure sensors
CONFIGURATION OF MPC4 / IOC4T CARDS
9.2 Connecting vibration and pressure sensors
The IOC4T panel has four screw terminals for each of the four measurement channels. These
terminals are as follows:
This section contains a description of the measurement channel inputs and includes typical
connection diagrams.
The MPC4 / IOC4T card pair can be used to power sensors having built-in or integrally
attached signal conditioners, providing the current requirement is 25 mA. In cases where
this built-in power supply capability is insufficient, an external power supply must be used.
Table 9-2 shows when this is necessary.
PS Power supply for transducer or signal conditioner.
HI
LO
SHIELD Terminal for connecting the shield of the transmission cable.
Differential input for
the signal.

Table of Contents

Other manuals for Meggitt VM600

Related product manuals