Programming
132
Programs with recommended
load ratio
(lb:gal/kg:l drum volume)
Absorption
of laundry
(Example)
Max.
Wash-to-liquid ratio
(lb:gal/kg:l liquid)
2.2:5/1:20 Low
(PES/BW mixed fibres)
2.2:2/1:8 to 2.2:2.5/1:10
2.2:2.5/1:10* Medium
(Cotton flat woven)
2.2:1.3/1:5 to
2.2:1.6/1:6
2.2:2.5/1:10* High
(Cotton toweling)
2.2:1.3/1:5 to
2.2:1.8/1:7
* e.g. Chemo-thermal disinfection program
Approve
When the Approve option is selected the program is allocated pro-
gram approval.
A program which is not approved cannot be started "Approval" sta-
tus.
Access
Lock
Create
Program header
:
:
No
Yes
Select the "Approve" menu option.
You have the following options:
– No
– Yes
Lock
When the lock option is selected a program is allocated program
locking.
If a program is started, after one minute it can no longer be stopped
or cancelled with the finish button.
The door can only be opened at the end of the program.
Peak load
Create
Program header
:
:
YesLock
Yes
Select the "Lock" menu option.
You have the following options:
– No
– Yes
Peak-load
When Peak load is selected the program is allocated a peak load
function.