Programming
143
21. Dispensing
stop 2
Settings as for Dispensing stop 1
22. Level stop 2
Settings as for Level stop 1
23. Wash time 2
Settings as for Wash time 1
24. Cool Down
Cooling the water to a defined temperature before drainage.
Choose from the following options:
– No
Water cooling does not take place.
– Automatic
There is a staged water intake via the valves which are defined in "In-
take path2", with a cooling speed of von 6°F (3°C) /min until the
maximum level for the machine is reached. Then drainage to water
level, again a staged water intake etc. until 113°F / 45°C water tem-
perature is reached. If the programmed target level is the same as the
maximum level for the machine, this is reduced by 30%.
– User defined
Cooling temperature from 68 to 203°F /20 to 95°C
Cooling speed from 1 to 20°C/Min.
25. Wash time 3
Settings as for Wash time 1
26. Program stop
2
Settings as for Program stop 1
27. Program stop
signal 2
Settings as for Program stop signal 1
28. Drainage path
1
The point at which the water should leave the machine, and where it
should drain to is set.
Choose from the following options:
– No
Draining of water does not occur. During the spin cycle, the drain
valve is opened at speeds> 70rpm.
– Drain
The drain valve is activated.
– Memory
The drained water is transferred to the water recycling system.
– Empty reservoir
The WRS tank is emptied.
– Clean
The water is circulated.