EasyManua.ls Logo

Miele PW 811 - Basic Program Lock and Buzzer

Miele PW 811
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
147
– Dispensing throughput (D1 to D13)
– Dispensing correction factor (D1 to D 13)
– Dispenser level reminder (D 1 to D 13)
– Password
– Medium water pressure
– Heater rating
– Customer data
– Currency
Save set parameters
Set the parameters.
Press the "Save" button to save the parameters set.
Saving is carried out and the display jumps back to the sub-menu.
Tip: When the button is pressed, or if after 30 seconds no button
has been pressed, the settings are not saved and the display returns
to the main menu.
Memory function
The Temperature and Spin speed program parameters for those pro-
grams which can be changed before the program start, are saved af-
ter the start of the program. In addition, the button functions are not
reset at the end of the program. These appear again with each new
program selection.
Options:
– No
– Yes
Basic program
lock
The programs in this defined program area cannot be changed,
deleted or overwritten.
Options:
– No
– User-defined from: 1to999
Buzzer
If "Yes" is programmed, the buzzer is activated along with the pro-
gramme stop signal 1 and 2, the block end signal and the fault stop
signal. The buzzer frequency is increased with the fault stop signal.
The buzzer is switched off after 5 minutes or when the multifunction
selector is operated.
If "No" is programmed, the buzzer is switched off.
Options:
– No
– Yes

Table of Contents