Programming
141
Gentle 3/27 Sec. Wash / Pause
User-defined:
On time 2 to 99 sec.
Off time 2 to 99 sec.
Speed
No
Normal
Scooping
User-defined 20 to 70 rpm
Agitation start:
Automatic load control
0mm to Level 1
Water level
0mm to Level 1
Amount of water
0 l to Level 1
Load/liquid ratio
1:0 to 1:20kg/l
15. Level stop 1
Regulation of water inlet
Choose from the following options:
– No
Water flows in simultaneously with subsequent program stages Dis-
pensing phase 1 and 2, Movement from level and Wash time 1 and 2.
These program stages are dovetailed with the water intake.
– Yes
First the water intake to the defined level occurs and then subsequent
program stages are completed. The program process stops during
water intake. Rotation . Drum rotation takes over from "Movement
from level".
16. Wash time 1
Drum rotation with the defined rhythm and speed occurs within the
time specified.
Choose from the following options:
– No
– User-defined