Washing without detergent compartment
27
Dispensing calibration
Dispensing pump 1
V: 100 ml
0/1
0st: P: No
Tip: The dispensing amount can be set from 0 to 9999 ml in 1 ml
steps.
Press multifunction button 0/1
The dispensing tube will fill up.
Press the0/1 button to stop the process.
Place the hose of the dispenser pump which is being checked at an
upward gradient in a measuring vessel.
Irritant detergents.
Irritant for skin and eyes
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing "Back".
Dispensing calibration
Main menu
Dispensing pump 1
Dispensing pump 2
Select a dispenser pump.
Dispensing calibration
Dispensing pump 1
0/1
0 st:
P: No
V: 100 ml
Press multifunction button0/1 .
Stop the pump by pressing the 0/1 button, or it will stop automatically
after 60seconds.
Measure the amount of liquid dispensed into the measuring vessel.
Dispensing calibration
Dispensing pump 1
0/1
30 st: P: 200 ml/minV: 100 ml
Enter the measured value into the"V:" field.
The throughput P is calculated in ml/min. by the controls.
Press the "Save" button.
The measured value is allocated to the pump.
Reconnect the hose.