177
Error
number
Message Cause Corrective action
129 Battery Exchange The internal clock battery
is spent and must be
replaced.
Contact your local dealer or our
service office.
12a HDC SPEED A problem was detected
with the print head control.
Turn off the main power and wait a
while before turning back on.
"Turning Off the Power"(P. 31)
130 HD DATA SEQ A problem was detected
with the print head control.
147 DS-IC BUSY Ink IC control abnormality
detected.
148 E-LOG SEQ A log control abnormality
was detected.
154 Main PCB V05 A problem was detected
with the main PCB 5V
power supply.
155 Main PCB V42-1 A problem was detected
with the main PCB 42V
power supply.
171 NEW HEAD CONNECT A new print head
connection was detected.
186 HDC OVERFLOW/HDC
UNDERFLOW
A problem was detected
with the print head control.
187 HDC SLEW RATE
188 HDC MEMORY
18e FLS NOT COMP A problem was detected
with the print head control.
18f OFFSET START [1]
18f OFFSET END [1]
1b8 HEAD XHOT A problem was detected
with the print head.
201 Command Error Data other than print (RIP)
data was received, or a
problem was detected
with the print (RIP) data
received.
1. Clear the data and resend.
2. Check the USB/Ether cable connection.
Connecting a PC to the Product
3. Use a compatible cable. Connecting a
PC to the Product
4. Turn off the main power and wait a
while before turning back on.
202 Parameter Error A problem was detected
with the print (RIP) data
received.
206 Print Mode Error Print (RIP) data was
received with print
parameters that do not
allow printing.
Change the output parameters and
profile using RIP software.
20A Driver Version Printing is not possible
because the Mimaki driver
version is old.
Install the latest Mimaki driver
available from:
https://mimaki.com/download/
inkjet.html
303 PCB MAIN ET A problem was detected
with the main PCB.
1. Turn off the main power and wait a
while before turning back on.
"Turning Off the Power"(P. 31)