Chapter 7 Troubleshooting
177
Error
number
Message Cause Corrective action
129 Battery Exchange • The internal clock battery
is spent and must be
replaced.
• Contact your local dealer or our
service office.
12a HDC SPEED • A problem was detected
with the print head control.
• Turn off the main power and wait a
while before turning back on.
"Turning Off the Power"(P. 31)
130 HD DATA SEQ • A problem was detected
with the print head control.
147 DS-IC BUSY • Ink IC control abnormality
detected.
148 E-LOG SEQ • A log control abnormality
was detected.
154 Main PCB V05 • A problem was detected
with the main PCB 5V
power supply.
155 Main PCB V42-1 • A problem was detected
with the main PCB 42V
power supply.
171 NEW HEAD CONNECT • A new print head
connection was detected.
186 HDC OVERFLOW/HDC
UNDERFLOW
• A problem was detected
with the print head control.
187 HDC SLEW RATE
188 HDC MEMORY
18e FLS NOT COMP • A problem was detected
with the print head control.
18f OFFSET START [1]
18f OFFSET END [1]
1b8 HEAD XHOT • A problem was detected
with the print head.
201 Command Error • Data other than print (RIP)
data was received, or a
problem was detected
with the print (RIP) data
received.
1. Clear the data and resend.
2. Check the USB/Ether cable connection.
Connecting a PC to the Product
3. Use a compatible cable. Connecting a
PC to the Product
4. Turn off the main power and wait a
while before turning back on.
202 Parameter Error • A problem was detected
with the print (RIP) data
received.
206 Print Mode Error • Print (RIP) data was
received with print
parameters that do not
allow printing.
• Change the output parameters and
profile using RIP software.
20A Driver Version • Printing is not possible
because the Mimaki driver
version is old.
• Install the latest Mimaki driver
available from:
https://mimaki.com/download/
inkjet.html
303 PCB MAIN ET • A problem was detected
with the main PCB.
1. Turn off the main power and wait a
while before turning back on.
"Turning Off the Power"(P. 31)
7