Purpose
This manual provides information to assist service personnel in performing
maintenance, and repair procedures that may be required to support ZS3 Ultrasound
System.
The Mindray/Zonare ZS3 Ultrasound System is used for ultrasound evaluation of the
following applications: Opthalmic; Fetal; Abdominal (renal, GYN/Pelvic); Intra-operative
(abdominal, thoracic(cardiac), and vascular); Intraoperative (Neuro); Pediatric; Small
organ (thyroid, breast, testes, etc); Neonatal cephalic; Adult Cephalic/Transcranial; Trans-
rectal; Trans-vaginal; Trans-esoph.(non-Card); Musculoskeletal (Conventional);
Musculoskeletal (Superficial); Cardiac Adult; Cardiac Pediatric; Trans-esoph. (Cardiac);
Intra-cardiac; Peripheral vessel. Users include ultrasound imaging technicians
(sonographers) and physicians. Mindray/Zonare Ultrasound Imaging Systems may be
used in a hospital (e.g., imaging laboratory, emergency room, patient bedside, and
operating room), medical clinic, physician’s office or a mobile imaging center. Please
refer to the ZS3 Instructions For Use for more information.
The ZS3 Ultrasound System consists of two major components: 1) Cart; and, 2)
Transducer(s). The Cart contains the software driven imaging electronics and user
interfaces (keyboard, monitor, handles, etc.). It houses the microprocessor, memory,
amplifiers and power supplies for the microprocessor. It sends electrical currents to and
receives electrical pulses from the compatible transducers. The Cart performs the
calculations involved in processing the data to produce the displayed ultrasound
images. The ZS3 Cart is available in two options: with or without Echocardiography. The
Echocardiography option allows users to perform advanced cardiac and intracardiac
imaging and related functions beyond what is available without the echocardiography
option.
Included with the system are one or more Mindray/Zonare Curvilinear, Endocavity,
Linear, or Phased array transducers allowing for many clinical applications. Accessories
include, but are not limited to the Mindray/Zonare ZPAK Battery and off-the-shelf
components: bar code reader, foot pedal, printers, biopsy guides, ECG cables and a
wireless Ethernet interface. Case studies can be stored to USB memory stick, and other
industry standard archiving devices.
Note: The availability of options may be limited based on country or region of use.
Definitions/Acronyms
2D: ................ Two dimensional (B-Mode, Color mode)
BMP: ............. Bit MaP
C-Mode: ....... Color Flow Mode (Doppler)
D-Mode: ....... Doppler (Pulsed Wave) Mode
DICOM: ......... Digital Imaging and COmmunication in Medicine