138
C
ABLING INTERFACES
CHAPTER 4 INSTALLATION
NOTE:
Only the FXS interfaces on the mainboard of the SMB Controller (FXS1...FXS6) support this feature.
FXS interfaces on the card ETAB4 cannot be used.
The customer is responsible for all copyright matters relating to any music playback.
FXS mode: Control output
If an FXS interface is configured as a control output, the signal can be used to control external devices or
equipment (e.g. heating, alarm or outdoor lighting systems).
The no-load voltage is 24 VDC; the current is limited to 25 mA. A connected relay must be of the type 24
VDC and must not draw more than 300 mW in power.
There are no special requirements for the cables.
CAUTION: Control outputs must have a floating connection.
Figure 4.46: Connection for FXS mode: Control output
[1] The diode is necessary, in order to avoid unwanted voltages at the control output during the the
start-up phase of the communication server.
Figure 4.47: Connection for FXS mode: Control output
Table 4.31:Technical data for FXS mode: External audio source
Input impedance approx. 15 kW
Input level configurable
Input circuit asymmetrical
Output resistance audio source 1 kW
Installation cable NF cable screened (required for low levels)