117
CHAPTER 3 CPU MODULE FUNCTIONS
3
3.17 Local Device Monitor/Test
(2) Device test procedure
1. Connect a personal computer to the CPU module
2. Display a program in ladder mode
3. Switching to the monitor mode
[Online] [Monitor] monitor mode
4. Select [Local device monitor] from the monitor window.
(3) Number of programs that can be monitored/tested
Local devices of 16 programs can be simultaneously monitored or tested from multiple programming tools.
(4) Precautions
One programming tool can monitor or test local devices in one program at a time. Local devices in multiple
programs cannot be monitored or tested simultaneously.
When local devices in a stand-by type program are monitored, data in local devices are saved and restored.
For this reason, the scan time increases.
When local devices in a fixed scan execution type program are monitored, data in local devices cannot be
acquired and "0" is displayed.