Communications Card Description ZB4-601-IF1, ZB4-609-IF1 4-33
Moeller 07/01 AWB-C2700-1347GB
TELEMECANIQUE
PLC Type Protocol PLC Port Parameters
TSX17
UNI-Telway TSX-ACC5 9600 baud, 8 data bits, 1 stop bit, parity odd
DRIVER DESIGNATION (11, 4) : BUS > TELWAY-M (MPB.BIN)
SUPPORTED DATA TYPES : W
WIRING LIST
RS 485
Signal Pin Pin Signal
A3 14A
SG 5 8 SG
B7 7B
5Earth
12 UTW
Coding example : 4 Parity
11 N4 (16)
ACC5 as Slave 1 3 N3 (8)
(Station number 1) 10 N2 (4)
2N1 (2)
9N0 (1)
ZB4-601/609-IF1 TSX-ACC5
(9 pole male)
(15 pole male)
“Parity” also be connected to “Earth” if the
number of the “Nx” connected to earth is
even.
Detailed notes on the address coding are
given in the manual on the UNI-Telway Bus
(TSX D24 004G).
NOTES
With this connection the ZB4-601/609-IF1 acts as master. However, only one slave can be run with this
(point-to-point).
Configure the communication module using a dialogue block, as described in the manual on the TSX
ACC5 (section 2.1-1). Use the following parameters:
UTW : 9600 baud, ODD Parity, 8 data bits, 1 stop bit
In this case the station number of the ZB4-601/609-IF1 is 0 (Master).
The set station number on the ACC5 must correspond to the station number to be addressed via the ZB4-
601/609-IF1.
WIRING NOTES
The connections described are made directly on the communications card without the use of a two-way
branch (e. g.: TSX SCA62).
In this case, however no BUS terminating resistors are provided at the PLC end. This is permissible for a
point-to-point connection.
In this case switch on the bus terminating resistors of the RS 485 on the ZB4-601/609-IF1.
If several stations are connected to the same BUS, a two-way branch with bus terminating resistors
switched on must be used for at least the first and last PLC. If the ZB4-601/609-IF1 is at the end of the
link, its bus terminating resistors must be switched on (see configuration of the ZB4-601/609-IF1).