EasyManua.ls Logo

MYDATA MY500 JetPrinter - Page 70

MYDATA MY500 JetPrinter
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Machine Systems MY500 JetPrinter MYDATA
3 - 24 Rev. 0003 2008-06 P-030-0014-EN – Service Manual
Approved
Designed
Drawn
Date Sign.
Title
Document number
Sheet Revision
Part of
This document is our property. It must not be copied and its contents m ust not be imparted
to third persons without our written permission. Infringement of the above will be prosecuted.
2008-06-10
2008-04-28
System Safety
00042
ZG-030-0013
JE
JE
MY500 System Overview
6
()
H:\Petter\blockschema\System_Safety.SchDoc
1
2
3
4
AUX EMERG
4 pole XLR
1
2
3
4
SRE1
4 pole MiniFit Jr
Safety Relay
MOT-CTRL
ESTOP_BUTTON
HOOD
GND
+24VS
LSafe
HSafe
10k
Vz = 10V
+5V
GND
10k
GND
+5V
10k
Auxin0
GND
Auxin1
SAF-CAN (Calib. Station)
Auxin4
1615
13
2
14
2019
910
1
7 8
18 17
56
1211
SAFETY RELAY2
NAIS SF4-DC24V
1
2
3
4
SRE2
4 pole MiniFit Jr
AC_Line_R
AC_Line_S
+24V
RelayHi
RelayLo
Loop1
Loop2
AC1
AC2
+24VS
CTRL-PIM
Extension
/EStopped
10k
Vz = 10V
+5V
120E
Safety Loop Enable
PTC
To Laser and
To Conveyor
+24VS'
Stepper Motor
To Piezo Amplifier
LSafeRelay
HSafeRelay
8
1
XSAFE
4
5
pulled down by
GND
2 x ULN2003 at CTRL-INT
+5V
10k
ESTOP_BUTTON
10k
Vz = 10V
+5V
GND
10k
GND
+5V
10k
Auxin0
SAF-CAN (LighTower)
Auxin4
SAF-CAN
(AirCtrl)
Optional safety
button extention
S2 S3 S4
1
2
3
4
1
2
3
4
XMMIS
2x Mini-Fit
N'
MOT-PBP
P'
AMP Y
AMP X
7 8
9 10
5 6
3 4
2 1
SAFETY RELAY
SIM312-24V
MOT-PIM
1
2
3
4
SRE
4pole MINIFIT male
GND
+24V_Relay
HSafeRelay
LSafeRelay
HResetLoop
P
N
+24V_Relay
+24V
HResetLoop
P'
N'
+24V
HResetLoop
LResetLoop
P
N
+24V
PTC
RUE250
+24VS
+24VS
1N4002
SMINT-SAFCAN
(MotorControl)
RIGHT FRONT
MMI - module
7 8
9 10
5 6
3 4
2 1
SAFETY RELAY
SIM312-24V
P
N
+24V
P
N
+24V
2008-06-10 PS

Table of Contents