MYDATA MY500 JetPrinter Routine Maintenance
P-030-0014-EN – Service Manual Rev. 0003 2008-06 5 - 19
Lubricating X wagon Rail – 720 Operating Hours
This preventive maintenance shall only be carried out by authorized service
engineers.
WARNING! Before commencing, switch the power off, and lock out and tag
the main switch.
Every 720 hours the X-wagon rail, and bearings need to be lubricated.
Equipment
– Grease gun from the spare parts kit.
– AFA lubricant, MYDATA part number K-035-0095.
Performing
1. Turn off the power, and lock and tag the main switch.
2. Open the machine front hood.
3. Apply a thin layer of grease on the rail, using the grease gun. Wipe away
any excess grease with a lint-free cloth.
4. Move the X wagon along the rail a couple of times, to distribute the
grease evenly.
5. Close the front hood.
6. Remove the lock ant tag, and restart the machine.
Figure 5-19. X-wagon rail and bearings.