Machine Systems MY500 JetPrinter MYDATA
3 - 26 Rev. 0003 2008-06 P-030-0014-EN – Service Manual
Approved
Designed
Drawn
Date Sign.
Title
Document number
Sheet Revision
Part of
This document is our property. It must not be copied and its contents m ust not be imparted
to third persons without our written permission. Infringement of the above will be prosecuted.
2008-06-10
2008-04-28
CAN Network
00044
ZG-030-0013
JE
JE
MY500 System Overview
6
()
Node Functional Description
H:\Petter\blockschema\System_CANnodes.SchDoc
CassetteInterface
Digital inputs
Piezo
PC
8 - EStopped
7 - Red LED control
5 - Power +15V (camera)
1 - AC line voltage
Digital outputs
Analog inputs
Analog outputs
0 - High voltage DC output control (only from DSP)
Digital inputs
8 - Paste level (not implemented)
9 - Cassette position (not implemented)
4 - Power +24V (stepper)
1 - Cassette temperature
0 - X motor temperature
Analog inputs
Analog outputs
Special functions
3 - Stepper peak current limit (only from DSP)
2 - X encoder quality signal
ULAN channel 5, holder EEPROM (only from PC)
Conveyor NextMovePCI
Special functions
Digital inputs
AirCtrl
4 - EStop
0 - Air pressure warning
1 - Cassette lock
4 - X motor cooling
4 - I/O power +24V
5 - Auxout total current
Digital outputs
Analog inputs
Analog outputs
0 - Paste pressure
Digital inputs
LightTower
1 - Hood safety switch
0 - Red lamp
1 - Yellow lamp
3 - White lamp
2 - Green lamp
Digital outputs
0 - Filterbox air flow
2 - Cassette cooling
Digital inputs
CalibStation
0 - Safety button
5 - Auxout0 readback
0 - Paper motor enable
Digital outputs
C32 DSP
C32 DSP
Generic MY500 node
6 - Power +24V
7 - Power +5V
Analog inputs
Special functions
ULAN channel 7, computer board EEPROM (only from PC)
(C32 DSP)
CMOT
Connection to comms array, SDO index 0x2000
ULAN channel 6, mother board EEPROM (only from PC)
5 - Y motor cooling
Baldor
IXXAT
0 - High voltage DC input
2 - Pulse output current
3 - Pulse output voltage
4 - Peak current
5 - Power +18V
Not populated
CAN-HUB
Stepper velocity controller
Piezo pulse generator
Special functions
4 - EStop
5 - Auxout0 readback
4 - I/O power +24V
5 - Auxout total current
Analog inputs
4 - I/O power +24V
5 - Auxout total current
Analog inputs
4 - EStop
5 - Auxout0 readback
1 - Safety button (big red @ keyboard)
2 - Filterbox air flow surveillance
2 - SMEMA upstream
3 - SMEMA downstream
4 - SMEMA upstream
5 - SMEMA downstream
CAN Kingdom
PWM cassette heater
0 - (Air pressure warning)
2 - (Filterbox air flow surveillance)
1 - (Fan current)
1 - Fan current
1110 13 12
-
2
04
ULAN channel 4, ejector EEPROM (only from PC)
4 - /EActivate
1 - 5 CTRL-BOX EEPROM connections
1 - Pulse slope control
3 - Height indicator
3 - Cassette unlock
Digital inputs
ExtConvCtrl
0 - RS485 TXD
1 - RS485 RXD
8
MotorControl
7
Digital inputs
4 - 7 MOT-BOX EEPROM connections
3 - CANPower
4 - FanMonitor1
Analog inputs
2 - HSafeMonitor
0 - X_encSetup
1 - Y_encSetup
5 - FanMonitor2
0 - RS232 TXD
Digital Outputs
0 - AmpMuxX
1 - AmpMuxY
2 - AmpReset
1 - RS232 RXD
EEPROM channels
(node 10)
1 uLAN_INT
2 uLAN_HUB
3 uLAN_HIP
4 uLAN_PBP
5 uLAN_PIM
EEPROM channels
(node 7)
4 uLAN_MPBP
5 uLAN_MPIM
(big red @ machine right)
2008-06-10 PS