Routine Maintenance MY500 JetPrinter MYDATA
5 - 2 Rev. 0003 2008-06 P-030-0014-EN – Service Manual
Maintenance intervals
The intervals for daily and weekly maintenance are fixed. All other
maintenance intervals are dependent on the usage of the machine.
CAUTION! The maintenance intervals apply to a clean environment and an
indoor temperature of maximum 25°C. If operated in a dusty environment, or
higher temperature, it is strongly recommended to perform cleaning and
lubrication after half the stated time intervals.
Cleaning optics
– If the optical surface is very dusty or dirty, remove the dust and dirt
using a spray can with clean air intended for optics. Other air may
contain particles and grease from air pumps and valves which may be
harmful to the optics.
– Clean optics by folding a clean lint-free cloth to the width of the
optics. Apply a small amount of isopropyl alcohol, and gently pass the
cloth over the surface. Ensure there is no film left on the surface after
the use of alcohol. An alternative is to use pre-moistened cleaning
towlettes, especially developed for cleaning of optics.
– Do not use abrasives or cleaning solutions!
Lubricants
Unless otherwise stated, use Shell Tellus oil and OKS 270 grease. Oil and
grease should be applied just to give just a thin film.
Information about Material Safety are found in the Safety chapter.
Spare parts
Part numbers for spare parts are found in the Spare Parts Catalog.