For BLF message receiving office (Office B, C)
DESCRIPTION DATA
Provide Busy Lamp Field (BLF)-CCIS to each
CCH number.
(1)
(2)
Y=30
0-7: CCH No.
0: To provide
To the virtual LEN, assign the station number
of the other office which is accommodated to
the BLF, as follows.
For closed numbering system: station number
For open numbering system: Access code + of-
fice number + station number
(1)
(2)
000-255: Virtual LEN
X-XXXXXXXX: Station No.
NOTE: Amount of Access Code + Office
No. + Station No. must be no
more than 8 digits.
Specify whether the station number assigned
by CM11 is own office station or the other of-
fice station
(1)
(2)
Y=40
X-XXXXXXXX: Station No. assigned by
CM11
0 : Other office station
1 : Own office station
Assign the station number of the other office to
the keys on the DSS Console.
(1)
(2)
DSS Console No. (00-31) + + DSS Key
No. (00-59)
X-XXXXXXXX: Station No. assigned by
CM11
Assign the station number of the other office to
the One Touch keys on the D
term
.
(1)
(2)
Y=0
X YY Z
X : 0-9: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
X-XXXXXXXX: Station No. assigned by
CM11
Specify whether the line lockout indication is
available on the DSS Console.
(1)
(2)
274
0 : Available
1 : Not available
START
CMA7
CM11
CM13
CM97
,
CM74
CM08