CHAPTER 3 SYSTEM DATA PROGRAMMING
– 146 – NWA-008853-001 Rev.3.0
97ch3002.fm
BUSY VERIFICATION-CCIS
General Description
This feature permits an Attendant, via the Attendant Console on the 2400 IPX or the 2000 IPS, to interrupt
a busy station’s call at another switching office connected through CCIS.
Programming
DESCRIPTION DATA
Provide the system with Busy Verification. (1)
(2)
012
1 : Available
Specify whether the Warning Tone is sent to
the connected parties.
Three burst tone
[Other than New Zealand]
One burst tone
[New Zealand Only]
(1)
(2)
046
0: Not sent
1: To send
Specify the Warning Tone sent to connected
parties.
(1)
(2)
045
0: Only once
1 : Every 4 seconds
Specify the Warning Tone sent to the outside
party.
(1)
(2)
076
0: Not sent
1: To send
Assign Service Restriction Class A to the re-
quired stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Busy Verification in Service Restriction
Class A assigned by CM12 Y=02.
(1)
Y=09
00-15: Service Restriction Class A
assigned by CM12 Y=02
1 : Allow
START
CM08
CM12
CM15
END
BUSY VERIFICATION-CCIS