CHAPTER 3 SYSTEM DATA PROGRAMMING
– 237 – NWA-008853-001 Rev.3.0
97ch3003.fm
Centralized Billing Programming Steps for Pattern 4
To SMDR 0: Setting of billing information from Center Offices.
To SMDR 1: Setting of billing information from Local Office.
Use two SMDR terminals, one for Port 0 and one for Port 1.
CENTER OFFICE LOCAL OFFICE A/B
CM05 Y=0>XX : 45 (AP00) 45 (AP00)
CMDD99>0000 : CCC (Data All Clear) CCC
CMDD00>3 : 1 (Center Office) 0 (Local Office)
CMDD02>0
>1
>2
: No. of call record for SMDR 1
: 0 (Not record)
: 0 (Not record)
Desired setting
Desired setting
No. of call record Local Office
CMDD98>0000 : CCC CCC
CM08>800
>368
>378
: 1 (AP00)
: 0 (Center Office)
: 1 (Not Local Office)
1
1 (Local Office)
0 (Not Center Office)
CMA7 Y=03>0 : 1 (Distant Office is Local Office) 0 (Distant Office is Center Office)
=04>0 : NONE Point Code of Center Office
CMDD01>239
CM04 Y=01>09
>06
>03
CMDD01>100
>101
CMDD10>000
>100
>001
>101
>002
>102
>003
>103
>004
>104
>005
>105
>006
>106
>010
>110
: 1 (SMDR 0)
: Desired setting
: 3 (AP00 with MRCA program)
: 2 (AP00 with MRCA program)
: 3 (SMDR with NEAX 2400 IMS Format)
: 3 (SMDR with NEAX 2400 IMS Format)
: 1 (SMDR 0)
: 2 (SMDR 1)
: Data Speed (Port 0)
: Data Speed (Port 1)
: Stop Bit (Port 0)
: Stop Bit (Port 1)
: Data Length (Port 0)
: Data Length (Port 1)
: Parity (Port 0)
: Parity (Port 1)
: 48 (Port 0)
: 48 (Port 1)
: UA (Port 0)
: UA (Port 1)
: 0 (Port 0)
: 0 (Port 1)
0 (Not Centralized Billing Office)
Desired setting
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
CM12 Y=45 : XX (Station Class No.) XX (Station Class No.)
CM60 Y=32 : XX (Class No.) XX (Class No.)
CENTRALIZED BILLING-CCIS