EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 273

NEC NEAX 2000 IPS
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 3 SYSTEM DATA PROGRAMMING
– 259 – NWA-008853-001 Rev.3.0
97ch3004.fm
DESCRIPTION DATA
Specify to outgoing/incoming call capability
on each Route Restriction Class (RCA-RCH)
assigned by CM12 Y=01 to each route.
NOTE: For the route assigned as C.O. line
by CM35 Y=56 (RCF), 57 (RCG),
58 (RCH) are automatically as-
signed to “Restricted”.
(1)
(2)
Y=51 (RCA)
Y=52 (RCB)
Y=53 (RCC)
Y=54 (RCD)
Y=55 (RCE)
Y=56 (RCF)
Y=57 (RCG)
Y=58 (RCH)
Y=61 (RCA)
Y=62 (RCB)
Y=63 (RCC)
Y=64 (RCD)
Y=65 (RCE)
Y=66 (RCF)
Y=67 (RCG)
Y=68 (RCH)
00-63: Trunk Route No.
0 : Restricted
1 : Allow
To deny access to particular trunk groups from
dial-repeating Tie trunks, specify the combina-
tion of trunk route restricting the Trunk-to-
Trunk Connection.
(1)
(2)
Y=0
XX ZZ
XX: 00-63 (Incoming Trunk [Tie Trunk]
Route)
ZZ : 00-63 (Outgoing Trunk [Miscella-
neous Trunk] Route)
0: Allow
A
CM35
Restriction of
Outgoing Connection
Restriction of
Incoming Connection
CM36
END
DELUXE TRAVELING CLASS MARK-CCIS

Table of Contents

Other manuals for NEC NEAX 2000 IPS