CHAPTER 3 SYSTEM DATA PROGRAMMING
– 298 – NWA-008853-001 Rev.3.0
97ch3004.fm
DESCRIPTION DATA
Specify the kind of the Attendant Console.
(1)
(2)
Y=22
0-7: ATTCON No.
0 : DESKCON
1: ATTCON
Allocate the ATT Group number to each AT-
TCON/DESKCON.
(1)
(2)
Y=00
0-7: ATTCON No.
0-3: ATT Group 0-3
Specify the Master ATTCON/DESKCON
within the ATT Group assigned by CM60
Y=00.
(1)
(2)
Y=01
0-7: ATTCON No.
0 : Master ATT
1: Not Master ATT
When providing 2nd Ringing feature on the
DESKCON, make Off-Hook Ringing effec-
tive. (for DESKCON only)
(1)
(2)
Y=16
0-7: ATTCON No.
0: Effective
Allow or restrict the system to keep the volume
level changed by the volume button on
DESKCON, after the call is finished. (for
DESKCON only)
(1)
(2)
Y=23
0-7: ATTCON No.
0 : Allow
1 : Restricted
Specify the tenants to be handled by each ATT
Group.
(1)
(2)
Y=0-3 ATT Group 0-3
00-63: Tenant No.
0 : To handle
1 : Not handled
C
CM60
INITIAL
INITIAL
INITIAL
INITIAL
INITIAL
CM62
INITIAL
D
JANUARY/31/2006
MULTIPLE CONSOLE OPERATION-CCIS

Table of Contents

Other manuals for NEC NEAX 2000 IPS