Example for Data Assignment:
Network station number for a D
term
on the 2000 IPS office: 60000
Network station number for a D
term
on the 2400 IPX office: 60001
Area Code Development Pattern number: 0
Trunk route number: 01
Command Code 1st Data 2nd Data Description
10
20 Y=0-3
8A Y=A000
8A Y=4000-4007
8A Y=0000-0255
000-763
6
3
6
1
60000
815
4005
0000
00001
Network station No. 60000
(Assignment for a network station No.
60001 to the LEN is not necessary.)
5 digits network station
Area Code Development Pattern No. 5
Route Pattern No. 000
LCR Pattern No. 000 + trunk route No. 01