CHAPTER 3 SYSTEM DATA PROGRAMMING
– 319 – NWA-008853-001 Rev.3.0
97ch3005.fm
DESCRIPTION DATA
Specify the maximum number of digits dialed
by the calling party. The maximum number of
digits including the area codes should be as-
signed to each area code.
(1)
(2)
Y=0-4
Area Code Development Pattern No. 0-4
assigned by CM8A Y=A000
X-X...X: Area Code dialed
(Maximum 8 digits)
01-24 : 1-24 digits
25-79 : 25-79 digits
Assign the area code to be restricted and the
Toll Restriction Pattern number assigned by
CM81 to the Area Code Development Pattern
number assigned by CM35 Y=76. For exam-
ple, to provide the Trunk Restriction Class
RCB, RCC, RCD, RCE, RCF, RCG and RCH
with the Toll Restriction for Area Code “00”:
•Area Code=00
Toll Restriction Pattern=05
(See Toll Restriction Pattern Table on
CM81.)
If the Toll Restriction Pattern for the same area
code is changed according to the Tenant, Date,
and Time, add the required patterns (Tenant,
Date, and Time) to the area code.
(1)
(2)
Y=4000-4004
Area Code Development Pattern No. 0-4
X-X...X: Area Code (Maximum 8 digits)
B000-B015: Toll Restriction Pattern No.
00-15
B
CM85
CM8A
2000
-2007
3000
-3003
0000
-0255
1000
-1015
5000
-5255
Area
Code
4000
-4004
Time
Pattern
Tenant
Pattern
Route
Pattern
Data
Pattern
TR
Pattern
Toll Restriction
Pattern 00-15