CHAPTER 3 SYSTEM DATA PROGRAMMING
– 334 – NWA-008853-001 Rev.3.0
97ch3005.fm
DESCRIPTION DATA
Assign the Toll Restriction Patterns with eight
kinds of Trunk Restriction Classes assigned by
CM35 Y=97. Toll Restriction Pattern 00-15
have already been programmed as shown be-
low. If a new Restriction Pattern is required,
change the data for Restriction Patterns 01-13
(00, 14 and 15 are fixed).
(1)
(2)
Y=01-13
Toll Restriction Pattern No. 01-13
1-8: Trunk Restriction Class
0: Restricted
3: Allowed
Specify the maximum number of digits dialed
by the calling party. The maximum number of
digits including the area codes should be as-
signed to each area code.
(1)
(2)
Y=0-7
Area Code Development Pattern No. 0-7
assigned by CM8A Y=A000
X-X...X: Area Code dialed
(Maximum 8 digits)
01-24 : 1-24 digits
25-79 : 25-79 digits
A
CM81
0: Restricted
3: Allowed
TRUNK
RESTRICTION
CLASS
Y
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
1 RCA 3033300033333030
2 RCB 3033000033000030
3 RCC 3030000030000030
4 RCD 3000000000000030
5 RCE 3000000000000030
6 RCF 0000000000000030
7 RCG 0000000000000030
8 RCH 0000000000000030
CM85
B
TRUNK-TO-TRUNK RESTRICTION-CCIS