NEAX2400 ICS Business Features and Specifications
NDA-24143, Issue 4
Page 233
Distinctive Ringing - Caller ID D-153
D-153 Distinctive Ringing - Caller ID
(Series 6300 software feature)
General Description
This feature is a part of CALLER ID service. This feature provides distinctive ringing pattern (0, 1, 5, 6 or
7) according to the received calling number.
Operating Procedure
No manual operation is required.
Service Conditions
1. This feature is available for Series 6300 software or later.
2. On-off timing of Ringer Patterns 0, 1, 5, 6 and 7 can be changed using the ASYD command.
However, system data assigned for Ringer Patterns 6 and 7 cannot be applied to the analog
telephone.
3. Ringer patterns 6 and 7 can be used for ELC circuit cards and the following LC circuit cards. With
regard to other LC cards, ringer patterns 0, 1, 5 are available for this feature.
4. When the calling number is not received, this service is not available. (i.e. The ringing pattern is
determined according to the parameter DR of ARTD command.)
5. The calling number for this service is assigned to the parameter CID of ACID command. When
only the first part of the calling number is assigned to the CID, this feature is applied to any calling
number that begins with the assigned number. For example, when 0471 is assigned to the CID,
this feature is applied to any calling number that begins with 0471 such as 0471-12-3456 and
0471-23-4567.
6. The following numbers cannot be assigned to the parameter CID of ACID command:
The first part of an assigned number
The number whose first part is the same as the already assigned number
For example, when 123 is already assigned to the CID, such numbers as 1, 12 or 1234
cannot be assigned.
7. When the calling number is received via CCIS line, this feature is available for the first 16 digits
(provided that 1 is assigned to CND: 29 (CI) of ARTE command).
8. This service is available only for stations (single line telephone and D
term
).
Circuit Card Name Firmware Remarks
PA-16LCBE SP-785
PA-16LCBJ SP-3001
PA-16LCBJ-A SP-3102
PA-16LCBJ-B SP-3251
SN868 DRE-A SW-228
SN880 DRE-A SW-228

Table of Contents