NEAX2400 ICS Business Features and Specifications
Page 508
NDA-24143, Issue 4
T-2 Three-Way Calling
Interactions
1. A station in an established three-way connection cannot flash the switchhook to activate a
feature. The flash disconnects the last party connected.
2. All three-way calls are protected by privacy. No more than three ports can be bridged together
at one time, unless PRIVACY RELEASE [P-18] is being used.
3. If a three-way call includes two trunks and the station hangs up, the trunks will release, unless
the trunks are allowed TRUNK-TO-TRUNK CONNECTION [T-10] via the ARRC command, ARI-
D-RES.