NEAX2400 ICS Business Features and Specifications
Page 58
NDA-24143, Issue 4
A-125 Analog Caller ID (Class SM)
Service Conditions (cont’d)
17. The maximum number of calling numbers varies depending on the system configuration as
shown below.
IMG
x
: approximately 20,000
IMG
xh
/IMG
dxh
/UMG
x
: approximately 30,000
18. When a call is transferred to a trunk, the transferred party’s D
term
LCD displays as shown below.
Transferred To Display During Transfer Display After Transfer
CCIS Trunk Transferring Party’s Number
Calling Number received from the C.O.
line
Q-SIG Trunk Transferring Party’s Number Transferring Party’s Number
IS-11572 Trunk Transferring Party’s Number Transferring Party’s Number