3-48
3
STN
5: BSCheck (BSChk)
Check the Backsight direction
Press the [5:BSChk] on the station setup
menu to enter the BS check function.
Sight the BS and press the [ENT] or [4]
key to reset the horizontal angle to the HA
set in the last station setup.
Press the [ESC] or [1] to abort the process
and return to the BMS.
HA: Current HA reading
BS: The HA to the BS at the last station setup.
HA:103 °50’34 ”0
BS:103 °50’30 ”5
Abrt Rst
If you have not finished setting up the station, the Backsight check
function is not available. An error screen will be shown.
(See p.8-1, 3