5-
4
●
5
-
2
-
2
Mu
lti
-
Turn Ty
pe MRE
Sensor (
3
-
phase
)
■
MRE
-
32SS062FAL
U
nits
: m
m
■
MRE
-
G
□
SS062FAL
(
□
: 32, 64, 128, 160, 256, 320, 640,
1280, 2560)
■
RB
-
02 (Option)
L type flange
-
mount f
ixture
for
MRE
-
32SS062FAL
and
MRE
-G
□
SS062FAL
28
30
Table of Contents
Table of Contents
5
Functions
12
Position Setting Function
12
Automatic Positioning Function (AUTO)
12
Unidirectional Positioning
12
Starting Operation from Inside STOP Zone
14
Timer Settings
15
Learning Function
16
Limit Switch Output Function
18
Protected Switch Function
18
Current Position Preset Function
19
Machine Position Check Function
19
Communication Function
20
Self-Diagnosis Function
20
Specifications Section
21
Specifications
22
VS-12PB Specifications
22
General Specifications
22
Performance Specifications
22
Input/Output Signal Specifications
23
ABSOCODER Sensor Specifications
24
Multi-Turn Type MRE Sensor (2-Phase)
24
Multi-Turn Type MRE Sensor (3-Phase)
24
Linear Type VLS Sensor
25
Sensor Cable
25
Outer Dimensions
26
VS-12PB Controller
26
ABSOCODER Sensors
27
Multi-Turn Type MRE Sensor (2-Phase)
27
Multi-Turn Type MRE Sensor (3-Phase)
29
Cable
32
6-1 Ordering Information 6-1
34
Installation
37
Verifying the Shipping Container Contents
38
Installation Condition & Precautions
39
Controller Installation
39
ABSOCODER Sensor Installation
40
Wiring
41
Terminal Board & Connector Connection
41
Power Supply Connection
42
Control I/O Signals
43
BCD Input/Output Connections
47
Communication Connector (RS-232C, RS-422)
49
Sensor Cable Connection
50
Operation Section
51
Operation
51
Before Beginning Operation
52
Control Panel Nomenclature
52
Operation Sequence
55
Power on
56
Designating the Initial Settings
56
Basic Initial Settings
56
Initial Settings
57
Sensor Rotation (Travel) Direction Settings
58
Decimal Point Setting (Initial No.91)
59
Sensor Selection (Initial No.92)
59
Scale Length Setting (Initial No.93)
60
Minimum Current Position Value (Initial No.94)
61
Current Position Value Setting (Initial No.95)
62
Other Initial Settings
63
Parameter Settings
64
Setting Items for Dual Speed Positioning
64
Basic Parameter Setting Procedure
65
Other Parameter Settings
66
Run
68
AUTO Positioning
69
JOG Operation
72
Limit Switch Output Settings
73
Limit Switch Settings
73
Protected Switch Function
76
Dog Output Delete
77
Dog Output Insert
78
Channel Delete
78
Program Batch Delete
79
Program Batch Copy
80
Other Operations
81
Use of Password to Protect Data
81
All Data Delete (Initialize)
82
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the NSD VARILIMIT VS-12PB and is the answer not in the manual?
Ask a question
NSD VARILIMIT VS-12PB Specifications
General
Brand
NSD
Model
VARILIMIT VS-12PB
Category
Switch
Language
English
Related product manuals
NSD Varicam VS-5ED
60 pages
NSD VARICAM VS-5FD
130 pages
NSD Varicam VS-5E-1
60 pages
NSD Varicam VS-5EX-1
60 pages
NSD Varicam VS-5E Series
60 pages
NSD VARICAM VS-5F Series
130 pages