Loading...
9
Table 2-3 Connection Object #1 (Class ID 0x05,Instance ID 0x01:Explicit Messaging Connection
Name
ID/
Code
Description Get/Set TYPE Value
Class Attribute
No support
Class Service
No support
Instance Attribute
State
Get
USINT
0
5
2
Instance type
Get
USINT
0
3
Transport Class trigger
Get
BYTE
0x83
4
Production Connection ID
Get
UINT
5
Consumed Connection ID
Get
UINT
6
Initial Communication
Characteristics
Get BYTE 0x21
7
Produced Connection size
Get
UINT
0x0A
8
Consumed Connection size
Get
UINT
0x0D
9
Expected packet rate
Get/Set
UINT
0,2
12
Watchdog timeout action
Get/SET
USINT
1,3
13
Produced connection path
length
Get UINT
14
Produced connection path
Get
Array of USINT
15
Consumed connection path
length
Get UINT
16
Consumed connection path
Get
Array of USINT
17
Production inhibit time
Get
UINT
0
Instance Service
0x05
Reset
0x0E
Get Attribute Single
0x10
Set Attribute Single
Table 2-4 Connection Object #2 Class ID 0x05,Instance ID 0x02:I/O Messaging Connection
Name
ID/
Code
Description Get/Set TYPE Value
Class Attribute
No support
Class Service
No support
Instance Attribute
State
Get
USINT
0
5
2
Instance type
Get
USINT
1
3
Transport Class trigger
Get
BYTE
0x83
4
Production Connection ID
Get
UINT
5
Consumed Connection ID
Get
UINT
6
Initial Communication
Characteristics
Get BYTE 1
7
Produced Connection size
Get
UINT
8
8
Consumed Connection size
Get
UINT
8
9
Expected packet rate
Get/Set
UINT
0,2
12
Watchdog timeout action
Get
USINT
0,1,2
13
Produced connection path
length
Get UINT
14
Produced connection path
Get
Array of USINT
15
Consumed connection path
length
Get UINT
16
Consumed connection path
Get
Array of USINT
17
Production inhibit time
Get
UINT
0
Instance Service
0x05
Reset
0x0E
Get Attribute Single
0x10
Set Attribute Single

Table of Contents