3-7
3.5 Buffer Memory List
Reading and writing of internal VS-212DN data (buffer memory) is possible using the DeviceNet.
I/O
Address
Write Name
Data
format
Initial
value
Data range Content
Parameter
No.
0 R
1-axis manual mode,
input/output status
WORD
* VS-212DN can only save data items which have parameter Nos. Items without parameter Nos. are
initialized at power off.
* "Write conditions" include the following:
R: Enable reading only
W: Writing always enabled.
PW: Writing always enabled on condition that the sequence mode is "Parameter", and "PLC Ready"
status is "1".
IW: Writing always enabled on condition that the sequence mode is "Initial Setting" and "PLC Ready"
status is "1". (The current position setting's "write selection" item must also be "1".)
LW: Writing is always enabled, but data can be saved in memory only when the sequence mode is
"Program", and "PLC Ready" status is "1".
(1) System Parameter
I/O
Address
Write Name
Data
format
Initial
value
Data range
Description
Parameter
No.
0
R
Axis 1 Manual mode, I/O status
WORD
1
R
Axis 2 Manual mode, I/O status
WORD
2
R
Axis 1 Error code
USINT
0
99
3
R
Axis 2 Error code
USINT
0
99
4
W
Sequence mode selection
BYTE
5
R
Sequence mode answer-back
BYTE
6 PW Axis 1 Function selection USINT
0
0
For limit switch output and
positioning functions
50
1
For limit switch output
function
2
For current position
detection function
7 PW Axis 2 Function selection USINT
0
0
For limit switch output and
positioning functions
50 1
For limit switch output
function
2
For current position
detection function
Address is specified when
using the DeviceNet I/O to
read or write data from the
PLC.
Condition for data
writing from DeviceNet
Data name
Data format:
BYTE: 8bit
WORD: 16bit
USINT: 8bit integer without
plus/minus mark
DINT: 32 bit integer
UDINT:32bit integer without mark
Factory setting
Data setting
range or change
range.
Data
setting
Parameter No. when
specifying setting from the
external setting unit
(VS-T62 or VS-T62B).
Setting from the external
setting unit is only possible
for items with numbers.