Environmental
Specification Description
Ozone emis-
sions
during printing: <= 1 mg/hr
Optimum tem-
perature
17-34 ºC (62.6-93.2 ºF)
For printing on light-weight media the temperature must be between 17-28 ºC
(62.6-82.4 ºF).
Relative humid-
ity
20-80%
For printing on light-weight media the relative humidity must be between
40-70%.
Altitude Lower than 2,000 m above sea level
Room size and
ventilation or
air change rate
at room size
Recommended room volume >= 75 m
3
Recommended air change rate >= 300 m
3
/h
NOTE
This is the ventilation requirement for the printer, additional to the
standard building ventilation requirements.
Sound power
level
Standby: < 69 dB(A)
Print: < 84 dB(A)
Power con-
sumption of the
printer
Off mode: 6 W
Sleep mode engine: 32 W
Sleep mode controller: 44 W
Standby mode: 0,9 kW
Operation mode at 80 g/m² / 20 lb bond:
• VP6180; 4.0 kW
• VP6220: 4,3 kW
• VP6270: 4,4 kW
• VP6330: 4,9 kW
Environmental
290
Chapter 15 - Specifications
Océ VarioPrint 6000 line