Parameters That Can Be Allocated for Programless Communications Appendix
Parameters That Can Be Allocated for Programless
Communications
The following table lists the parameters that can be allocated to programless communications.
Function Parameter Attribute Upload Download Remarks
Status Device A Status Common --- (See note.) Monitoring only
Device Error Status Common --- (See note.) Monitoring only
Configuration Error A Status Common --- (See note.) Monitoring only
Configuration Error B Status Common --- (See note.) Monitoring only
Internal Communications Error Status Common --- (See note.) Monitoring only
I/O Error Status Common --- (See note.) Monitoring only
I/O Alarm A Status Common --- (See note.) Monitoring only
I/O Alarm B Status Common --- (See note.) Monitoring only
I/O Notification A Status Common --- (See note.) Monitoring only
Error Channel A Status Common --- (See note.) Monitoring only
Basic Unit/Expand Unit Error Common --- (See note.) Monitoring only
Basic Unit/Expand Unit Alarm Common --- (See note.) Monitoring only
Output Status Common --- (See note.) Monitoring only
Device B Status Common --- (See note.) Monitoring only
HB Alarm Heater Current Value 1 Monitor Common --- (See note.) Monitoring only
Leakage Current Value 1 Monitor Common --- (See note.) Monitoring only
Heater Current Value 2 Monitor Common --- (See note.) Monitoring only
Leakage Current Value 2 Monitor Common --- (See note.) Monitoring only
Error Status 1 Common --- (See note.) Monitoring only
Error Status 2 Common --- (See note.) Monitoring only
Heater Burnout 1 Detection Common ●●
HS Alarm 1 Common ●●
Heater Overcurrent 1 Detection Common ●●
Heater Burnout 2 Detection Common ●●
HS Alarm 2 Common ●●
Heater Overcurrent 2 Detection Common ●●
Monitoring Process Value CH --- (See note.) Monitoring only
Channel Status CH --- (See note.) Monitoring only
Channel Alarm Status CH --- (See note.) Monitoring only
Internal SP CH --- (See note.) Monitoring only
Local SP Monitor CH --- (See note.) Monitoring only
Remote SP Monitor CH --- (See note.) Monitoring only
Bank No. Monitor CH --- (See note.) Monitoring only
MV Monitor (Heating) CH --- (See note.) Monitoring only
MV Monitor (Cooling) CH --- (See note.) Monitoring only
Decimal Point Monitor CH --- (See note.) Monitoring only
Target value Present Bank Set Point CH ●●
Present Bank SP Ramp Rise Value CH ●●
Present Bank SP Ramp Fall Value CH ●●
SP Upper Limit CH ●●
SP Lower Limit CH ●●
Alarms Present Bank Alarm Value 1 CH ●●
Present Bank Alarm Upper Limit Value 1 CH ●●
Present Bank Alarm Lower Limit Value 1 CH ●●
Present Bank Alarm Value 2 CH ●●
Present Bank Alarm Upper Limit Value 2 CH ●●
Present Bank Alarm Lower Limit Value 2 CH ●●
Present Bank Alarm Value 3 CH ●●
Present Bank Alarm Upper Limit Value 3 CH ●●
Present Bank Alarm Lower Limit Value 3 CH ●●
Inputs Input Digital Filter CH ●●
Input Value 1 for Input Correction CH ●●
Input Shift 1 CH ●●
Input Value 2 for Input Correction CH ●●
Input Shift 2 CH ●●