Chapter3 Indicator/Input & Output Setting
F3SJ-A
User’s Manual
What can be done by the setting tool
Setting Change
• For Basic System
Configure in a bulk in case of a series connection. (to be written into the primary sensor only)
If wiring is for auto reset, the interlock function won’t work regardless of these functional settings.
• For Muting System
Interlock state can be provided to auxiliary output or external indicator output.
- Auxiliary Output (Non-Safety Output) p.94
- External Indicator Output (Non-Safety Output) p.98
Function Initial Setting Available Setup Item Setting Console PC Tool For F3SJ
Start Interlock Enabled Enable/disable
Restart Interlock Enabled Enable/disable
Function Initial Setting Available Setup Item Setting Console PC Tool For F3SJ
Start Interlock Disabled Enable/disable
Restart Interlock Disabled Enable/disable
Reset input
ON
OFF
Safety output
ON
OFF
250ms or longer
*1
Sensor status
Interlock state
Power supply
ON
OFF
Normal operation
Start interlock: Enabled
Restart interlock: Enabled
Start interlock: Disabled
Restart interlock: Disabled
Normal operation
Normal operation
Normal operation
Normal operation
Reset input
ON
OFF
Safety output
ON
OFF
Sensor status
Reset input
ON
OFF
Safety output
ON
OFF
Sensor status
Reset input
ON
OFF
Safety output
ON
OFF
F3SJ
Unblocked/Blocked
Sensor status
Power supply
ON
OFF
Unblocked
Blocked
F3SJ
Unblocked/Blocked
Unblocked
Blocked
F3SJ
Unblocked/Blocked
Unblocked
Blocked
F3SJ
Unblocked/Blocked
Unblocked
Blocked
250ms or longer *1
*1 For a muting system, 450ms or more.
Interlock state