65
F3SJ-A
User’s Manual
Chapter3 Protection of Setting by Password
What can be done by the setting tool
E
Protection of Setting by Password
Access Qualification
The setting tool has the following two access levels: a user level, in which setting information can only
be read out, and an administrator level, in which functional settings can be changed.
The administrator level requires a password to log in. The initial password for administrator login is
"0000".
Password Change
An administrator must change the password to prevent setting change by an operator.
Up to 4 (uppercase for alphabet) and 6 (lower and uppercase for alphabet) digits passwords can be set
for the setting console and PC tool for F3SJ respectively.
- If a password of 5 digits or more, or that includes lowercase alphabet, is set for the PC tool for F3SJ, a user cannot
log in by the setting console. If you want to use both of the PC tool for F3SJ and the setting console, you must use 4-
digit alphanumeric characters (uppercase) for your password.
- A password must be alphanumeric characters.
If You Forget the Password:
If you forget the password after changing it from the initial setting, contact your sales representative
with the serial number on the F3SJ receiver's label.
A master password will be issued to reset to the initial password “0000”.
Location of serial number p.58