7
F3SJ-A
User’s Manual
Chapter1 Application Examples
Overview and Specifications
E
For a System that Has a Machine Within a Detection Zone
When the Zone Is Fixed (Fixed Blanking Function):
For a system in which a fixed facility such as a worktable or a conveyor interrupts specific beams, the
fixed blanking function can be used to disable the specific beams.
When the Zone Is Movable (Floating Blanking Function):
If a part of the machine can move within the detection zone, the floating blanking function can be used
to disable a part of the detection zone.
You can configure a number of beams to be interrupted by an object so that the safety function works
only if more beams than the number are interrupted.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ Series and is the answer not in the manual?

Omron F3SJ Series Specifications

General IconGeneral
TypeSafety Light Curtain
Safety CategoryCategory 4
Protection RatingIP67
SILSIL3
Operating Temperature-10°C to +55°C
Detection MethodInfrared
Resolution14 mm
IP RatingIP67
CertificationCE
Power Supply Voltage24 VDC ±10%