8
Chapter1 Application Examples
F3SJ-A
User’s Manual
Overview and Specifications
To Notify a Person of Proximity to a Detection Zone
(Warning Zone Function)
This function notifies a person that he/she is getting close to a detection zone before activating the
safety functions. It can be used to prevent the unintended stopping of a machine due to the approach
of a person.
Part of a detection zone is configured as a warning zone.
Detection Zone
Detection Zone
Warning Zone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ Series and is the answer not in the manual?

Omron F3SJ Series Specifications

General IconGeneral
TypeSafety Light Curtain
Safety CategoryCategory 4
Protection RatingIP67
SILSIL3
Operating Temperature-10°C to +55°C
Detection MethodInfrared
Resolution14 mm
IP RatingIP67
CertificationCE
Power Supply Voltage24 VDC ±10%