153
F3SJ-A
User’s Manual
Chapter4 Mounting
Wiring/Installation
E
Mounting Procedure
1. Attach the top/bottom mounting brackets.
Place top/bottom mounting bracket (2) in the screw hole at the top/bottom of the F3SJ, and fasten it
using the included screw (M5x20). Insert the bracket's protrusion into the groove on the case when
attaching. Next, attach top/bottom mounting brackets (3) and (1) to top/bottom mounting bracket (2),
and fasten them lightly using the included screws (M3x8).
2. Attach the intermediate mounting brackets.
Insert intermediate brackets (2) and (3) into the grooves on the side of the case, and use the included
mounting screws (M3x10) to lightly fasten the brackets so that they are able to slide up and down the
case.
Mounting screw
(M5x20)
Top/bottom
mounting
bracket (2)
Mounting screw
(M3x8)
Top/bottom
mounting
bracket (3)
Top/bottom mounting
bracket (1)
Tighten lightly
Mounting
screw
(M3x10)
Intermediate
mounting
bracket (2)
Intermediate
mounting
bracket (3)
Attach so that the tooth shown in the dotted
circle is facing downward.
Tighten
lightly

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ Series and is the answer not in the manual?

Omron F3SJ Series Specifications

General IconGeneral
TypeSafety Light Curtain
Safety CategoryCategory 4
Protection RatingIP67
SILSIL3
Operating Temperature-10°C to +55°C
Detection MethodInfrared
Resolution14 mm
IP RatingIP67
CertificationCE
Power Supply Voltage24 VDC ±10%