EasyManua.ls Logo

Omron MX2 Series - Reduced Voltage Startup Selection; Frequency Jump Function

Omron MX2 Series
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Other Functions
7 - 36
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
Data
Default
data
Unit
b036
Reduced Voltage
Startup Selection
0: Reduced voltage startup disabled
1 (Reduced voltage startup time: short) to
255 (Reduced voltage startup time: long)
2
Related functions
b082
Parameter
No.
Function name
Data
Default
data
Unit
A063/A065/
A067
Jump Frequency 1/2/3
0.00 to 590.00
Set the center of the jump frequency.
*1
0.00
Hz
A064/A066/
A068
Jump Frequency Width
1/2/3
0.00 to 10.00 (100.00)
*2
Set 1/2 of the jump frequency width.
0.50
Hz

Table of Contents

Related product manuals