Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
Data
Default
data
Unit
b036
Reduced Voltage
Startup Selection
0: Reduced voltage startup disabled
1 (Reduced voltage startup time: short) to
255 (Reduced voltage startup time: long)
2
Related functions
b082
Parameter
No.
Function name
Data
Default
data
Unit
A063/A065/
A067
Jump Frequency 1/2/3
0.00 to 590.00
Set the center of the jump frequency.
*1
0.00
Hz
A064/A066/
A068
Jump Frequency Width
1/2/3
0.00 to 10.00 (100.00)
*2
Set 1/2 of the jump frequency width.
0.50
Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC