7 Other Functions
7 - 106
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
7-11 Option/Applied Functions (Group P)
7-11-1 Operation Selection on Option Error
Parameter
No.
Function name
Data
Default
data
Unit
P001
Operation Selection on Option Error
00: Trip
01: Continue operation
00
Parameter
No.
Function name
Data
Default
data
Unit
A017
DriveProgramming Function Selection
00: Disabled
01: Enabled (Start/stop via
multi-function input
PRG terminal)
02: Enabled (Start/stop via
power on/off)
00
P100 to
P131
DriveProgramming User Parameter U00
to U31
0. to 65535.
0.
7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC